HLK-PM01 - Converter AC/DC STEP-DOWN, AC IN 220V, DC OUT 5V, 0.6A
search
  • HLK-PM01 - Converter AC/DC STEP-DOWN, AC IN 220V, DC OUT 5V, 0.6A
  • HLK-PM01 - Converter AC/DC STEP-DOWN, AC IN 220V, DC OUT 5V, 0.6A
  • HLK-PM01 - Converter AC/DC STEP-DOWN, AC IN 220V, DC OUT 5V, 0.6A

HLK-PM01 - Converter AC/DC STEP-DOWN, AC IN 220V, DC OUT 5V, 0.6A

€6.70
Quantity
immediate delivery

 

Security policy

 

Delivery policy

Electrical characteristics:
1. The input (test) characteristics at room temperature.

Rated input voltage: 100-100. VAC
Input voltage range: 90-90. VAC
Maximum input current: 0.2 or less a.
Surge current input; 10 or less to
Maximum input voltage: 270 or less VAC
Input soft start: 50 or less MS
Low input voltage efficiency: Vin = 110 vac, output with 69 or more %
High input voltage: Vin = 220 vac, output with 70 or more %
Long-term reliability: MTBF 100,000 or more H.
No-load rated output voltage: +5 +/-0.1 VDc
Full rated output voltage: +5 +/-0.2 VDc A
Short-term maximum output current: P 1000 ma
Maximum output current for a long time: P 600 ma
Voltage Regulation: +/-0.2%
Load regulation: + / -0.5%
Output ripple and noise: (mvp-p) 50 or less.
Rated input voltage and output load. With 20MHZ bandwidth oscilloscope,.
10uF and 0.1uF capacitance load and test. the MV
Machine Overshoot Switch
(Rated input voltage, output voltage and 10% load) 5 or less % VO.
Output overcurrent protection
150-200% maximum load output
A.
Output short circuit protection
Directly to the output of the normal short circuit, the short circuit automatically returns to normal work after removal.
4. Security features:
4.1 The product design meets the requirements of UL, CE safety certification.
4.2 safety and electromagnetic compatibility
Input design uses UL 0.5A insurance;
PCB board made of double-sided copper clad boards is 94-where V0 fire rating level;
In accordance with safety standards UL1012 EN60950, UL60950
Insulation voltage I/p-o/P: 2500 vac
Insulation resistance I/p-o/P > 100 m ohms / 500 VDC 25 degrees 70% RH
Conduction and radiation in line with EN55011, EN55022 (CISPR22)
Electrostatic discharge IEC/EN 61000-4-2 Level 4 8 kv / 15 kv
Immunity to radiofrequency radiation IEC/EN 61000-4-3 can be found in the application
4.3 Safety design temperature
At normal temperature in our power capacitor, the main converter, so the surface temperature does not exceed 90 degrees; The biggest
The maximum temperature of the shell surface does not exceed 60 degrees;

180729